Specifications Performance Specifications | Flow range | ¡¾0.098ft/s ~ ¡¾16ft/s (¡¾0.03m/s ~ ¡¾5m/s) | Accuracy | ¡¾2.0% | Pipe size | DN20, DN25, DN32, DN40, DN50, DN65, DN80 | Fluid | Water | Pipe material | PVC, Carbon Steel, Stainless Steel, Copper | Function Specifications | Optional Outputs | TTL, RS485, 4-20mA, WiFi | Communication interface | WIFI(standard), TTL/RS485(optional), Support FUJI protocol and MODBUS protocol | Power supply | 10~36VDC/500mA | Temperature | Transmitter ambient temperature :14¢µ~122¢µ(-10¡É~50¡É) Transducer measurement medium:32¢µ~140¢µ(0¡É~60¡É) | Humidity | Up to 99% RH,non-condensing | Physical Specifications | Transmitter | PC/ABS | Keyboard | 3 touch Keys | Display | 1.44'' LCD | Protection Rate | Ip54 | Cable Length | Power cable: standard length 2m |
Cloud Service F3 provides wireless communication function, which can access the Internet via WLAN and upload data to a cloud server. Users can view flow data charts on mobile phones and PCs, and download statistical tables.
|